Remote Control Commands
R&S
®
SMBV100A
557Operating Manual 1407.6062.32 ─ 08
Parameters:
<Delay> float
Range: 0 to 100 000 Symbols
Increment: 1 symbol
*RST: 0 symbol
Example:
BB:DM:TRIG:OUTP2:DEL 16
sets a delay of 16 symbols for the signal on connector MARKER
2.
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MINimum?
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MAXimum?
The command queries the maximum marker delay for set-
ting :BB:DM:TRIG:OUTP:DEL:FIX ON.
Return values:
<Maximum> float
Example:
BB:DM:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:DM:TRIG:OUTP:DEL:MAX
queries the maximum of the dynamic range.
Response: 2000
the maximum for the marker delay setting is 2000 symbols.
Usage: Query only
[:SOURce<hw>]:BB:DM:TRIGger:RMODe?
The command displays the status of signal generation for all trigger modes with digital
modulation on.
Return values:
<RMode> STOP | RUN
RUN
The signal is generated. A trigger event occurred in the triggered
mode.
STOP
The signal is not generated. A trigger event did not occur in the
triggered modes, or signal generation was stopped by the com-
mand :BB:DM:TRIG:ARM:EXECute (armed trigger modes
only).
SOURce Subsystem