Remote Control Commands
R&S
®
SMBV100A
618Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:CORRection:CSET:DATA:POWer:POINts?
The command queries the number of level values in the selected table.
The numerical suffix at SOURce must not be used for this command.
Return values:
<Points> float
Example:
CORR:CSET '/var/smbv/Lists/ucor/ucor1'
selects the table ucor1.
CORR:CSET:DATA:POW:POIN?
queries the number of level values in the table ucor1.
Response: 440
the table ucor1 contains 440 level values.
Usage: Query only
[:SOURce<hw>]:CORRection:CSET:DATA[:SENSor<ch>][:POWer]:SONCe
The command fills the selected user correction list with the level values measured by the
power sensor for the given frequencies.
The power sensor used is selected by the suffix in key word SENSe of the command
header.
Suffix:
<ch>
.
1 .. 3
Suffix 1 denotes the sensor connected to the SENSOR connector,
suffix 2 the sensor connected first to one of the USB interfaces
and suffix 3 the sensor connected second to one of the USB inter-
faces.
Example:
CORR:CSET:DATA:SENS:POW:SONC
fills the user correction list with level values acquired by the power
sensor connector to the SENSOR connector.
Usage: Event
[:SOURce]:CORRection:CSET:DELete <Delete>
The command deletes the specified table.
The lists are stored with the fixed file extensions *.uco in a directory of the user's choice.
The directory applicable to the commands is defined with the command
MMEMory:CDIR. A path can also be specified in command :SOUR:CORR:CSET:CAT?,
in which case the file in the specified directory is deleted.
The numerical suffix under SOURce is irrelevant.
Setting parameters:
<Delete> <table name>