Remote Control Commands
R&S
®
SMBV100A
636Operating Manual 1407.6062.32 ─ 08
Parameters:
<Level> float
Range: 0.01 to 2
Increment: 0.01
*RST: 1
Default unit: V
Example:
INP:TRIG:LEV 1 V
a high/low threshold of 1 volt is set at all trigger and control signal
inputs of the baseband section. In the case of positive polarity, the
signal is high (active) for a signal voltage of 1 volt and higher.
[:SOURce]:INPut:TRIGger:SLOPe <Slope>
Sets the polarity of the active slope of an externally applied trigger signal at the trigger
input (BNC connector at the rear of the instrument).
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Example:
INP:TRIG:SLOP NEG
activates the falling slope of the external trigger signal at the trigger
input.
[:SOURce]:INPut:DELay:ADCState <State>
Enables/disables the automatic delay compensation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 637
[:SOURce]:INPut:DELay:SPOSition <Position>
Defines the position of the slave instrument in the daisy chain, where the slave directly
connected to the master instrument is the one with number 1, etc.
Parameters:
<Position> integer
Range: 1 to 10
Increment: 1
*RST: 1
Example:
see example for [:SOURce]:INPut:DELay:CLENgth<ch>
on page 637
SOURce Subsystem