Remote Control Commands
R&S
®
SMBV100A
646Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP:MODE <Mode>
This command activates (USER) or deactivates (DECimal) the user-defined step width
used when varying the level value with the level values UP/DOWN. The command is linked
to setting Variation Active for manual operation, i.e. the command also activates/deac-
tivates the user-defined step width used when varying the level value with the rotary knob.
Parameters:
<Mode> DECimal | USER
*RST: DECimal
Example:
IQ:OUTP:DIG:POW:STEP:MODE USER
actives the step width for level variation with the rotary knob (man-
ual operation) and with level values UP/DOWN (remote control).
Options: B13 and B18
[:
SOURce<hw>]:IQ:OUTPut:POWer:VIA <Via>
This command activates the selected I/Q output level entry fields of the currently selected
signal path in the status bar.
Parameters:
<Via> PEP | LEVel
PEP
The signal level is expressed in terms of a peak envelope power
value (PEP). The level entry fields and the corresponding units are
displayed in the status bar.
LEVel
The signal level is expressed in terms of a rms value. The level
entry field and the corresponding units are displayed in the status
bar.
*RST: PEP
Example:
IQ:OUTP:POW:VIA PEP
the I/Q-signal level is set via PEP for the signal of path A.
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe <SRate>
Using the sample rate source User the command sets the sample rate value of the output
signal. This command is not active for external clock sources
Parameters:
<SRate> float
Range: 400 to 100 MHz
Increment: 0.01 Hz
*RST: 1E8