Section 06 STEERING AND PROPULSION
Subsection 02 (iBR, REVERSE AND VTS)
219100963-011-002
The message LAUNCH ON will be displayed.
IVTS
219001878-201_b
To deactivate the Launch Control, press simulta-
neously both UP/DOWN buttons again.
The message LAUNCH OFF will be displayed.
Lock/Unlock iBR Actuator
Locking/Unlocking the iBR Actuator
When working on the iBR, lock the iBR to avoid
accidental movement.
In BUDS2, go to:
– Settings page
– iBR button
– Configuration - Lock/Unlock iBR
ADJUSTMENT
iBR FLASHING
NOTICE
Make sure the unit's battery is fully
charged before undertaking this operation.
NOTICE
Continuous power to the computer
is mandatory while performing this operation.
Perform after replacing the iBR actuator.
Connect the vehicle to the BRP diagnostic soft-
ware (BUDS2).
In BUDS2, go to:
– Flash page
– iBR button
Select the update file in the
VALID FIRMWARE
UPDATES
window and click
YES
when prompted.
sbs2017-00
5-003a
The following message will confirm that the up-
date has been donne successfully.
sbs2017
-005-004a
Click
OK
and proceed to the
IBRM
update.
iBRM FLASHING
NOTICE
Make sure the unit's battery is fully
charged before undertaking this operation.
NOTICE
Continuous power to the computer
is mandatory while performing this operation.
Perform after flashing the iBR.
Connect the vehicle to the BRP diagnostic soft-
ware (BUDS2).
In BUDS2, go to:
– Flash page
– iBRM button
Select the update file in the
VALID FIRMWARE
UPDATES
window and click
YES
when prompted.
172 219100963-018