Equipment Manuel for Booksize Power Modules
x Manual, (GH2), Edition 06.2005, 6SL3097-2AC00-0BP2
2.6 Line reactors for Active Line Modules...................................................................................... 2-20
2.6.1 Description ............................................................................................................................... 2-20
2.6.2 Safety information .................................................................................................................... 2-20
2.6.3 Connection description............................................................................................................. 2-21
2.6.3.1 Line/load connection ................................................................................................................ 2-22
2.6.4 Dimension drawing................................................................................................................... 2-23
2.6.5 Technical specifications ........................................................................................................... 2-24
2.7 Line reactors for Smart Line Modules ...................................................................................... 2-25
2.7.1 Description ............................................................................................................................... 2-25
2.7.2 Safety information .................................................................................................................... 2-25
2.7.3 Connection description............................................................................................................. 2-26
2.7.3.1 Line/load connection ................................................................................................................ 2-27
2.7.4 Dimension Drawings ................................................................................................................ 2-28
2.7.5 Technical specifications ........................................................................................................... 2-31
2.8 Line connection variations........................................................................................................ 2-32
2.8.1 Methods of line connection ...................................................................................................... 2-32
2.8.2 Operation of the line connection components on the supply network ..................................... 2-34
2.8.3 Operation of the line connection components via an autotransformer .................................... 2-35
2.8.4 Operation of the line connection components via an isolating transformer............................. 2-37
2.8.5 Line connection via a ground-fault circuit interrupter ............................................................... 2-39
3 Line Modules Booksize........................................................................................................................... 3-1
3.1 Introduction ................................................................................................................................ 3-1
3.2 Active Line Modules with Internal Air Cooling............................................................................ 3-3
3.2.1 Description ................................................................................................................................. 3-3
3.2.2 Safety information ...................................................................................................................... 3-4
3.2.3 Interface description................................................................................................................... 3-6
3.2.3.1 Overview .................................................................................................................................... 3-6
3.2.3.2 Connection example .................................................................................................................. 3-7
3.2.3.3 X1 line connection.....................................
................................................................................. 3-8
3.2.3.4 X200-X202 DRIVE-CLiQ interfaces ........................................................................................... 3-9
3.2.3.5 EP terminals X21 ..................................................................................................................... 3-10
3.2.3.6 X24 24 V terminal adapter ....................................................................................................... 3-11
3.2.3.7 Meaning of the LEDs on the active line module ...................................................................... 3-11
3.2.4 Dimension drawing................................................................................................................... 3-12
3.2.5 Installation ................................................................................................................................ 3-15
3.2.6 Electrical connection ................................................................................................................ 3-17
3.2.7 Technical specifications ........................................................................................................... 3-18
3.3 Active Line Modules with External Air Cooling......................................................................... 3-21
3.3.1 Description ............................................................................................................................... 3-21
3.3.2 Safety Information .................................................................................................................... 3-22
3.3.3 Interface description................................................................................................................. 3-24
3.3.3.1 Overview .................................................................................................................................. 3-24
3.3.3.2 Connection example ................................................................................................................ 3-25
3.3.3.3 Line connection ........................................................................................................................ 3-26
3.3.3.4 X200-X202 DRIVE-CLiQ interfaces ......................................................................................... 3-27
3.3.3.5 EP terminals X21 ..................................................................................................................... 3-28
3.3.3.6 X24 24 V terminal adapter ....................................................................................................... 3-28
3.3.3.7 Meaning of the LEDs on the active line module ...................................................................... 3-29
3.3.4 Dimension Drawings ................................................................................................................ 3-30
3.3.5 Installation ................................................................................................................................ 3-32
3.3.6 Electrical connection ................................................................................................................ 3-39
3.3.7 Technical specifications ........................................................................................................... 3-40

Table of Contents

Other manuals for Siemens SINAMICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS Series and is the answer not in the manual?

Siemens SINAMICS Series Specifications

General IconGeneral
Product LineSINAMICS
Cooling MethodAir-cooled, Liquid-cooled
Voltage Range200 V to 690 V
Power Range0.12kW - 250kW
Communication InterfacesPROFINET, PROFIBUS, Ethernet
Control ModesVector control, V/f control
Protection ClassIP20
TypeVariable Frequency Drives (VFD)

Related product manuals