Options
6.4 DRIVE-CLiQ Flanged Coupling
Equipment Manuel for Booksize Power Modules
Manual, (GH2), Edition 06.2005, 6SL3097-2AC00-0BP2
6-33
6.4 6.4 DRIVE-CLiQ Flanged Coupling
6.4.1 Description
The DRIVE-CLiQ Flanged Coupling is used to connect two DRIVE-CLiQ cables and can be
installed in a cabinet wall.
A DRIVE-CLiQ connection with degree of protection IP67 is implemented at the interface
outside the cabinet. Inside the cabinet, a connection with degree of protection IP20 is
implemented. The interface between the cabinet wall and the DRIVE-CLiQ Flanged Coupling
satisfies degree of protection IP54.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
6.4.2 Safety information
Caution
Only cables from Siemens must be used for DRIVE-CLiQ connections.