DC link components Booksize
5.4 Control Supply Module (CSM)
Equipment Manuel for Booksize Power Modules
Manual, (GH2), Edition 06.2005, 6SL3097-2AC00-0BP2
5-23
5.4.5 Technical Specifications
Table 5-9 Technical Specifications
Control Supply Module Unit Value
Input data
Line voltage
Line frequency
V
AC
Hz
3AC 380 - 480 V
AC
± 15%
47 to 63
Connection currents
Rated value (at U
eRated
)
A
AC
approx. 2
Starting current inrush A
AC
Max. 80
Power loss ride-through (at 400 V
AC
) ms 5
DC link voltage V
DC
430 to 882 (300 to 430 < 1 min)
Supply current (at 600 V) A
DC
1.1
Output data
Output voltage V
DC
26 +/- 2%
Output current A
DC
20
Startup to short-circuit
Short-circuit during operation
A
DC
A
DC
≤ 24
Normally 23 (continuous)
Current carrying capacity of the 24 V DC
busbars
A
DC
20
Efficiency U
aRated
I
aRated
- > 83%
Residual ripple (clock frequency approx.
50 kHz)
mV
pp
< 100
Cycle peaks (bandwidth 20 MHz) mV
pp
< 200
Power loss
1
W < 105
Weight kg 4.8
1
For an overview, see the power loss tables in Cabinet Design.