6.3 Creating a SIMATIC S7 project
6-148
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
Properties – PG/PC
Type:
Cancel
General
PROFIBUS
Help
New...
OK
1
3
2
MPI
Industrial Ethernet
Name
Delete
AssignmentInterface
New interface – Type selection
Subnet
4. After confirming with OK, the properties dialog box of the Ethernet interface
is displayed. Select the tab: Parameter (1) tab and enter the IP address and
subnet mask of the PG/PC (2).
Note
Determining the IP address and subnet mask of the PG/PC:
On the PG/PC: Windows XP taskbar: Start > Run, Command: ipconfig
Select the Ethernet connection already parameterized in the previous Sec-
tion 6.3.8, Page 6-145 as the subnet: ”Ethernet (1)” (3)
Click OK to confirm the dialog.
Properties – Ethernet interface
General
Set the MAC address/use ISO protocol
IP protocol is used
Gateway
Parameter
––– not networked
–––
No router
3
2
When selecting a subnet,
the next available addresses are suggested.
09–00–07–01–00–02
IP address:
OK
Address:
Ethernet (1)
Delete
Cancel
MAC address:
Subnet mask:
Subnet:
157.174.219.45
255.255.248.0
Use router
157.174.219.45
New...
Help
Properties...
1
Notice
The MAC address, IP address and subnet mask in the figure above are only
sample values!
6 PLC Commissionin