01/2007
8.6 DP slave: MCP 310
8-201
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
DP slave: MCP 310 is located under:
S Profile: Standard
PROFIBUS DP > Other field devices > NC/RC > Motion Control
> SINUMERIK MCP
Select the DP slave by left–clicking it in the hardware catalog: MCP 310
(SINUMERIK MCP) and drag it while holding down the mouse key onto the DP
master system in the station window.
The DP master system is displayed in the station window with the following
symbol:
When you release the left mouse key, DP slave: MCP is inserted in the configu-
ration.
Note
As you drag the DP slave the cursor appears as a circle with a slash through it.
When the cursor is positioned exactly over the DP master system, it changes to
a plus sign, and the DP slave can be added to the configuration.
When you have inserted DP slave: MCP 310 into the configuration, dialog
”Properties – PROFIBUS Interface SINUMERIK MCP” is displayed.
The following PROFIBUS parameters must either be set or verified:
PROFIBUS address
Transmission rate
Profile
Dialog box: Properties – PROFIBUS Interface SINUMERIK MCP
Tab card: Parameter
Address: <PROFIBUS address>
Button: ”Properties...”
Dialog box: Properties – PROFIBUS
Tab card: Network settings
Transmission rate: 12 Mbaud
Profile: DP
OK
OK
PROFIBUS
parameters
Dialog box
8 PROFIBUS DP Communication