01/2007
9.2 ONLINE commissioning
9-249
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) -- 01/2007 Edition
-- The following note lists the drives that require offline motor configuration
because the corresponding data cannot be determined online. Confirm
with OK.
Note
Motors with DRIVE CliQ interfaces do not require subsequent offline con-
figuration as the appropriate parameters can be determined online by
the STARTER.
-- Finally in the dialog box ”Automatic configuration” click the button:
”Close”.
4. Go offline before configuring the motors and encoder (see next s ection).
To do this click the button: ”Disconnect from target system”.
Project
Add i ndividual drive
Drive_Unit_Addr10
Topology
Overview
Automatic configuration
Configuration
Overview
STARTER -- Project
Project Edi t Target System V iew Tools Window Help
Drives
Control_Unit
Input/Output components
Infeed
Inserting drives
Drive_1
Drive_2
Drive_3
D
eComm
on
n
SI
MICS