097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 183
Troubleshooting
Troubleshooting with Error Messages
EPROTMM Expected output
protection
mismatch
There are less than two
Output Driver cards in the
indicated Output card pair.
1. Use the Retrieve
Equipment command to
see if the Output Driver
card slot is configured for
protection
(RTRV-EQPT::OUTa:<ctag
>
:::PARAMETER=EPROT;,
where a is the Output card
pair).
2. Install another Output
Driver card in the slot pair,
or reconfigure the Output
Driver card protection
using the Edit Equipment
command
(ED-EQPT::OUTa:<ctag>::
:
EPROT=b;, where a is the
Output card pair and b is
the protection
requirement). Refer to
EPROT (Protection), on
page 105 for details.
Table 5-2. Message Troubleshooting (Continued)
Event Code
Error Message
Condition
Description
Meaning Action