TMS320C6455
www.ti.com
SPRS276M –MAY 2005–REVISED MARCH 2012
7.7.3.6 PLL Controller Command Register
The PLL controller command register (PLLCMD) contains the command bit for GO operation. PLLCMD is
shown in Figure 7-16 and described in Table 7-24.
31 16
Reserved
R-0
15 2 1 0
Reserved Rsvd GOSET
R-0 R/W-0 R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Figure 7-16. PLL Controller Command Register (PLLCMD) [Hex Address: 029A 0138]
Table 7-24. PLL Controller Command Register (PLLCMD) Field Descriptions
Bit Field Value Description
31:2 Reserved 0 Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.
1 Reserved Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.
0 GOSET GO operation command for SYSCLK rate change and phase alignment. Before setting this bit to 1
to initiate a GO operation, check the GOSTAT bit in the PLLSTAT register to ensure all previous
GO operations have completed.
0 No effect. Write of 0 clears bit to 0.
1 Initiates GO operation. Write of 1 initiates GO operation. Once set, GOSET remains set but further
writes of 1 can initiate the GO operation.
Copyright © 2005–2012, Texas Instruments Incorporated C64x+ Peripheral Information and Electrical Specifications 141
Submit Documentation Feedback
Product Folder Link(s): TMS320C6455