USTER
®
HVI SPECTRUM
Instruction Manual
Uster Technologies, Inc. Chapter 14
Appendix • Page 14-10
2.8 Universal Record Format
All records transmitted from an
HVI SPECTRUM
instrument will contain a
header that describes the information contained within the record. This
record header follows:
<instrument type>@<module>@<record type>@<instrument
id>@<time>@<date>@<record specific fields>@<check sum>@<CR>
1. Instrument Type:
HVI SPECTRUM
: Record is from an
HVI SPECTRUM
Instrument.
2. Module:
Will be blank in the cases of start-dataset and stop-dataset.
IDENTIFIER DESCRIPTION
L&S
HVI SPECTRUM
Length and Strength
MIC
HVI SPECTRUM
Micronaire
C&T
HVI SPECTRUM
Color and Trash
SCI
HVI SPECTRUM
SCI
MST
HVI SPECTRUM
Moisture
MAT
HVI SPECTRUM
Maturity
UV
HVI SPECTRUM
UV
NEP
HVI SPECTRUM
NEP
Table 14-2: Module Identifier and Description