C H A P T E R 10 S P E C I F I C A T I O N S
AT5600 User Manual 98-119 issue 14 Page 216
10.2.8. VOC Test
The accuracy of the applied test voltage is 1%.
The measurement accuracy is based on the chosen test conditions, and is given
by:
where:
A
T
is the total accuracy (%)
A
R
is the basic relative accuracy (%)
A
C
is the calibration accuracy (%)
A
V
is the correction for voltage level (%)
where:


󰇛

󰇜
 󰇛

󰇜
where:
F
M
is the test frequency (Hz)
V
M
is the measured voltage (V)