B.3 Parameter Table
392 YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
U1-03
(42H)
Output Current
Displays the output current.
Note:The unit is expressed in 1 A for models CIMR-E4A0930 and 4A1200.
10 V: Drive rated
current
<19> <50> –
U1-04
(43H)
Control Method
0: V/f Control
5: Open Loop Vector Control for PM
No signal output
available
––
U1-06
(45H)
Output Voltage Reference
Displays the output voltage.
10 V: 200 Vrms
<18> 0.1 Vac –
U1-07
(46H)
DC Bus Voltage
Displays the DC bus voltage.
10 V: 400 V
<18> 1 Vdc –
U1-08
(47H)
Output Power
Displays the output power (this value is calculated internally).
10 V: Drive capacity
(motor capacity) kW
<22> –
U1-10
(49H)
Input Terminal Status
Displays the input terminal status.
No signal output
available
––
U1-11
(4AH)
Output Terminal Status
Displays the output terminal status.
No signal output
available
––
U1-12
(4BH)
Drive Status
Verifies the drive operation status.
No signal output
available
––
U1-13
(4EH)
Terminal A1 Input Level
Displays the signal level to analog input terminal A1.
10 V: 100% 0.1% –
No. (Addr.) Name Description
Analog Output
Level
Unit Page
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)
All Modes
Multi-Function
Digital Output
(terminal M1-M2)
Multi-Function
Digital Output
(terminal M3-M4)
Multi-Function
Not Used
Digital Output
(terminal M5-M6)
Fault Relay
(terminal MA-MC closed
MA-MC open)
All Modes
During run
During zero-speed
During REV
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
All Modes
SIEP_C710616_35.book 392 ページ 2015年11月30日 月曜日 午後2時2分