E.3 User Setting Table
YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual 465
d2-01 Frequency Reference Upper Limit
d2-02 Frequency Reference Lower Limit
d2-03 Master Speed Reference Lower Limit
d3-01 Jump Frequency 1
d3-02 Jump Frequency 2
d3-03 Jump Frequency 3
d3-04 Jump Frequency Width
d4-01 Frequency Reference Hold Function Selection
d4-10 Up/Down Frequency Reference Limit Selection
d6-01 Field Weakening Level
d6-02 Field Weakening Frequency Limit
d7-01 Offset Frequency 1
d7-02 Offset Frequency 2
d7-03 Offset Frequency 3
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Maximum Output Frequency
E1-05 Maximum Voltage
E1-06 Base Frequency
E1-07 Middle Output Frequency
E1-08 Middle Output Frequency Voltage
E1-09 Minimum Output Frequency
E1-10 Minimum Output Frequency Voltage
E1-11 Middle Output Frequency 2
E1-12 Middle Output Frequency Voltage 2
E1-13 Base Voltage
E2-01 Motor Rated Current
E2-02 Motor Rated Slip
E2-03 Motor No-Load Current
E2-04 Number of Motor Poles
E2-05 Motor Line-to-Line Resistance
E2-10 Motor Iron Loss for Torque Compensation
E2-11 Motor Rated Output
E5-01 Motor Code Selection
E5-02 Motor Rated Power
E5-03 Motor Rated Current
E5-04 Number of Motor Poles
E5-05 Motor Stator Resistance
E5-06 Motor d-Axis Inductance
E5-07 Motor q-Axis Inductance
E5-09 Motor Induction Voltage Constant 1
E5-24 Motor Induction Voltage Constant 2
E5-25 Polarity Judge Selection
F6-01 Communications Error Operation Selection
F6-02 External Fault from Comm. Option Detection Selection
F6-03 External Fault from Comm. Option Operation Selection
F6-04 bUS Error Detection Time
F6-07 NetRef/ComRef Function Selection
F6-08 Reset Communication Parameters
F6-10 CC-Link Node Address
F6-11 CC-Link Communications Speed
F6-14 CC-Link bUS Error Auto Reset
F6-20 MECHATROLINK Station Address
F6-21 MECHATROLINK Frame Size
F6-22 MECHATROLINK Link Speed
F6-23 MECHATROLINK Monitor Selection (E)
F6-24 MECHATROLINK Monitor Selection (F)
F6-25 Operation Selection at Watchdog Timer Error (E5)
F6-26 MECHATROLINK bUS Errors Detected
F6-30 PROFIBUS-DP Node Address
F6-31 PROFIBUS-DP Clear Mode Selection
F6-32 PROFIBUS-DP Data Format Selection
F6-35 CANopen Node ID Selection
F6-36 CANopen Communication Speed
F6-50 DeviceNet MAC Address
No. Name
User
Setting
F6-51 DeviceNet Communication Speed
F6-52 DeviceNet PCA Setting
F6-53 DeviceNet PPA Setting
F6-54 DeviceNet Idle Mode Fault Detection
F6-55 DeviceNet Baud Rate Monitor
F6-56 DeviceNet Speed Scaling
F6-57 DeviceNet Current Scaling
F6-58 DeviceNet Torque Scaling
F6-59 DeviceNet Power Scaling
F6-60 DeviceNet Voltage Scaling
F6-61 DeviceNet Time Scaling
F6-62 DeviceNet Heartbeat Interval
F6-63 DeviceNet Network MAC ID
H1-01
Multi-Function Digital Input Terminal S1 Function
Selection
H1-02
Multi-Function Digital Input Terminal S2 Function
Selection
H1-03
Multi-Function Digital Input Terminal S3 Function
Selection
H1-04
Multi-Function Digital Input Terminal S4 Function
Selection
H1-05
Multi-Function Digital Input Terminal S5 Function
Selection
H1-06
Multi-Function Digital Input Terminal S6 Function
Selection
H1-07
Multi-Function Digital Input Terminal S7 Function
Selection
H1-08
Multi-Function Digital Input Terminal S8 Function
Selection
H2-01 Terminal M1-M2 Function Selection (relay)
H2-02 Terminal M3-M4 Function Selection (photocoupler)
H2-03 Terminal M5-M6 Function Selection (photocoupler)
H2-06 Watt Hour Output Unit Selection
H3-01 Terminal A1 Signal Level Selection
H3-02 Terminal A1 Function Selection
H3-03 Terminal A1 Gain Setting
H3-04 Terminal A1 Bias Setting
H3-05 Terminal A3 Signal Level Selection
H3-06 Terminal A3 Function Selection
H3-07 Terminal A3 Gain Setting
H3-08 Terminal A3 Bias Setting
H3-09 Terminal A2 Signal Level Selection
H3-10 Terminal A2 Function Selection
H3-11 Terminal A2 Gain Setting
H3-12 Terminal A2 Bias Setting
H3-13 Analog Input Filter Time Constant
H3-14 Analog Input Terminal Enable Selection
H3-16 Terminal A1 Offset
H3-17 Terminal A2 Offset
H3-18 Terminal A3 Offset
H4-01
Multi-Function Analog Output Terminal FM Monitor
Selection
H4-02 Multi-Function Analog Output Terminal FM Gain
H4-03 Multi-Function Analog Output Terminal FM Bias
H4-04
Multi-Function Analog Output Terminal AM Monitor
Selection
H4-05 Multi-Function Analog Output Terminal AM Gain
H4-06 Multi-Function Analog Output Terminal AM Bias
H4-07
Multi-Function Analog Output Terminal FM Signal Level
Selection
H4-08
Multi-Function Analog Output Terminal AM Signal Level
Selection
H5-01 Drive Node Address
H5-02 Communication Speed Selection
H5-03 Communication Parity Selection
H5-04 Stopping Method After Communication Error (CE)
H5-05 Communication Fault Detection Selection
H5-06 Drive Transmit Wait Time