System Setup
9 - 138
Number Input of the Axis Data Coordinates
1. Select „METHOD“.
Each time [SELECT] is pressed, “MAX/MIN” and “CENTER POS” switch alternately.
2. Select „MAX/MIN“.
3. Input number for “MAX” and “MIN” data and press [ENTER].
The axis interference area is set.
Teaching corner
1. Select „METHOD“.
Each time you press [SELECT], the display alternates between „MAX/MIN“ and
„CENTER POS“.
2. Select „MAX/MIN“.