System Setup
9 - 300
NOTICE
When using the DSU/DSD instruction, the timer (TMR) must be set to the output signal. If
{WRITE} is press without setting the timer (TMR) to the output signal, the error message
“ERROR 4241: Safety logic circuit is not set correctly” is shown on the message area of the
programming pendant.
NOTICE
When using the DSU or DSD instruction, the signal status turns to “”only for 4 ms while
the conditions are satisfied, but it is too short for visual check. Thus, display chapter
9.26.5 "Signal list window" and the SAFETY LOGIC CIRCUIT window together to check
the ON/OFF status of the input signal.
<The safety logic circuit: example 6>
The following is the setting example of the one-second one-shot output signal when two
signals are turned ON at the same time.
1. The following safety logic circuit is created.
001 DSU #1 GSIN1AND DSU #1 GSIN2 #1 GSOUT1 TMR1
2. Select {WRITE} and then {CONFIRM} to enable the changed settings.
When the data is updated correctly, the status on the title line is changed from “NOT
DONE” to “DONE”.