EasyManua.ls Logo

YASKAWA MOTOMAN YRC1000 - Page 309

YASKAWA MOTOMAN YRC1000
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Setup
9 - 309
11. Perform the setting for the connected device to be monitored.
Specify the monitoring signal corresponding to the used GP safety output signal.
<When monitoring the connected device to which GSOUT1 and FSBOUT1 are
connected>
After completing the setting, press {WRITE}.
GP safety output signal Feedback signal (monitor-
ing signal)
GSOUT1 GSEDM1
GSOUT2 GSEDM2
The following signals can be specified only in the system where
the safety I/O expansion board (optional) is enabled.
FSBOUT1 (XOUT1) XEDM1
FSBOUT1 (XOUT2) XEDM2
FSBOUT1 (XOUT3) XEDM3
FSBOUT1 (XOUT4) XEDM4
FSBOUT1 (XOUT5) XEDM5
FSBOUT1 (XOUT6) XEDM6
FSBOUT1 (XOUT7) XEDM7
FSBOUT1 (XOUT8) XEDM8
FSBOUT1 (XOUT9) XEDM9
FSBOUT1 (XOUT10) XEDM10
FSBOUT1 (XOUT11) XEDM11
FSBOUT1 (XOUT12) XEDM12
FSBOUT1 (XOUT13) XEDM13
FSBOUT1 (XOUT14) XEDM14
FSBOUT1 (XOUT15) XEDM15
FSBOUT1 (XOUT16) XEDM16