System Backup
10 - 348
4. Select {AUTO BACKUP SET}.
The AUTO BACKUP SET display appears.
RESERVE TIME BACKUP
Set the backup function to valid or invalid in a specified cycle from a specified starting
time.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed alternately.
The reserve time can be set by inputting values in B,C and D in the display.
Every time values are set to these three items, reset the RESERVE TIME BACKUP to
VALID.
If these settings are incorrect, the RESERVE TIME BACKUP cannot be reset to VALID.
If so, check and then change the values to the correct settings.
BASE TIME
Specify the reference time to start reserve time backup.
The time elapsed from the reference time for a BACKUP CYCLE period is recognized
as the BACKUP TIME.
The first automatic backup is performed at the first BACKUP TIME after the power of
the robot controller is turned ON.
The automatic backup after the first time, is performed at the interval of BACKUP
CYCLES.
The reference time ranges from 0:00 to 23:59.
BACKUP CYCLE
Specify the length of time for a cycle to back up. After the first backup, the next
backup is performed automatically in the time specified in the BACKUP CYCLE.
Set the backup cycle in units of minutes. The cycle setting ranges from 10 to 9999
minutes, and is longer than the RETRY CYCLE.
RETRY CYCLE
Specify the length of time for a cycle to retry backing up when the backup operation is
suspended.
After being suspended, the backup is retried in the time specified in the RETRY CYCLE.
Set the retry cycle in units of minutes. The cycle setting ranges from 0 to 255, and is
shorter than the BACKUP CYCLE.
When it is set to 0, retry will not be performed.
MODE CHANGE BACKUP

Table of Contents

Related product manuals