Ascotel IntelliGate 2025/2045/2065
336 Call Routing Part 2
Tab. 2.65: Routing parameter settings
Routing without direct dialling
An incoming call from the public network is routed on to the private leased-line
network in accordance with the information relating to the PISN subscriber allo-
cated via the call distribution element.
This is useful in only a few instances since all the calls are routed via the same call
distribution element.
Parameter Parameter value
Trunk group 1:
Network interfaces Network interfaces in this trunk group
Incoming connection Number of connections allowed simultaneously
Network type Public
Protocol DSS1
Direct dialling plan 1 (number of a direct dialling plan)
Call Distribution Element 1 (relevant only if no suitable DD number is found)
Direct dialling plan 1:
DD number 30 2 (reference number of a call distribution element)
Call distribution element 2:
Destinations Switching position 1: 330 (PISN Subscriber)
Incoming connections Number of connections allowed simultaneously
Subscriber configuration PISN SC 330:
Route 2 (route reference number)
Number Not relevant in this case
Route 2:
Trunk groups 2 (reference number of one or more trunk group(s))
Digit barring Use or do not use digit barring
Outgoing connections Number of connections allowed simultaneously
Numbering plan identifier NPI PNP
Type of number TON Unknown
Trunk group 2:
Network interfaces Network interfaces of this trunk group
Network type Private
Protocol QSIG or QSIG / PSS1 ISO