Ascotel IntelliGate 2025/2045/2065
Part 5 Configuration Steps 859
Configuration of ports on an SB-8
If an SB-8 is operated on two AD2 interfaces, the ports have to be paired up. We
recommend that you always pair up two neighbouring ports to prevent any other
radio unit being configured in between. The pairing has to be cancelled again if
the ports are to be used for operation with two radio units.
Event message for local power supply on SB-8
In the following cases the SB-8 radio unit deactives the HF and triggers an event
message (see "Event types", page 914):
The "Local power supply" parameter is on "Yes" and the local power supply
fails.
No local power supply is installed and the "Local power supply" parameter
changes from "No" to "Yes".
Local power supply
1)
[Yes / No] Specified status of local power supply
Local power supply state
1)
[Inactive / Active] Actual status of local power supply
External antenna
1)
[Yes / No] Switchover between internal and external
antennas on an SB-8ANT
1)
Only SB-8
Parameter Parameter value Remarks