Ascotel IntelliGate 2025/2045/2065
Part 6 Function check 877
Fig. 6.1: PISN with leased-line networking
1. In PINX 1, only allocate to the route pointing to PINX 2 the trunk group con-
taining the lines to be tested (e.g. trunk group 5).
2. Move all the network interfaces in trunk group 5 - bar one - to another, empty
trunk group (in this example trunk group 20).
3. Call a subscriber on PINX 2.
4. Move the tested network interface to trunk group 20.
5. Move the next network interface to be tested from trunk group 20 to trunk
group 5.
6. Repeat steps 3 to 5 until all the lines have been tested.
7. Move all the network interfaces back into trunk group 5.
8. Repeat the procedure for all trunk groups with lines to PINX 2.
9. Allocate all the trunk groups back to the route.
Repeat steps 1 to 9 for all PINXs.
Function test for PISN – internal traffic
1. Set up at least one connection to each PINX.
2. Check the ringing pattern.
3. Check the display on the terminal.
haz0783aaxxa0
PINX 3
PINX 1
PINX 2 PINX 4