6166 DC Voltage Current Source Operation Manual
3.11.2 Restoring to Factory Default Settings
3-77
Table 3-13 Setting Parameter Initial Values (1 of 3)
6166 compatible 6166
USER parameter Source memory
Parameter
Initial
value
Power
ON
C
Z/
*RST
Initial
value
Factory
default
MENU
initializ
ation
Power
ON
*RST *CLS
C
(DCL)
*RCLx *SAVx RINI SINI RLOD RSAV RCLR
User parameter
Program function OFF Initial
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Source function VS Initial
value
Initial
value
Initial
value
VS Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Voltage auto range ON Initial
value
Initial
value
Initial
value
ON Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Voltage range 1 V Initial
value
Initial
value
Initial
value
1 V Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Voltage source value +0.0000
000 V
Initial
value
Initial
value
Initial
value
+0.0000
000 V
Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Current auto range ON Initial
value
Initial
value
Initial
value
ON Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Current range 1 mA Initial
value
Initial
value
Initial
value
1 mA Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Current source value +0.0000
00 mA
Initial
value
Initial
value
Initial
value
+0.0000
00 mA
Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Voltage limit value 130 V Initial
value
Initial
value
Initial
value
130 V Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Current limit value 125 mA Initial
value
Initial
value
Initial
value
125 mA Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Type of thermocou-
ple
Type T Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Thermocouple stan-
dard C1602
1995 Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Temperature for ther-
mal electromotive
force output
23ï€ ï‚°C Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Reference junction
temperature
0ï€ ï‚°C Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
EXT-GUARD OFF Saved
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
EXT-SENSE OFF Saved
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Discharge relay ON Saved
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Count fix ON*1 Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
First number 0 Saved
value
Initial
value
0 Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Last number 99 Saved
value
Initial
value
999 Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Scan Hold Saved
value
Initial
value
Hold Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Step time 1 sec Saved
value
Initial
value
1 sec Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Notice buzzer switch OFF Saved
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Limit detection
buzzer switch
OFF Saved
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Interlock OFF Saved
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
Display brightness 6 Saved
value
Initial
value
Initial
value
6 Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
LED brightness 2 Saved
value
Initial
value
Initial
value
2 Initial
value
Initial
value
Saved
value
Initial
value
USERx Setting
value
Initial
value
Initial
value
*1: In the 6161-compatible operation, the count fix function is always set to ON.