EasyManuals Logo

ADCMT 6166 User Manual

ADCMT 6166
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
6166 DC Voltage Current Source Operation Manual
3.11.2 Restoring to Factory Default Settings
3-79
Non-saved parameter
OPR/STBY STBY Initial
value
Initial
value
Initial
value
STBY Initial
value
Initial
value
Initial
value
Initial
value
Remote output buffer Empty Initial
value
Initial
value
Initial
value
Empty Initial
value
Initial
value
Initial
value
Initial
value
Initial
value
Initial
value
Remote input buffer Empty Initial
value
Initial
value
Initial
value
Empty Initial
value
Initial
value
Initial
value
Display ON/OFF ON Initial
value
ON Initial
value
Initial
value
Initial
value
Memory setting
mode
OFF Initial
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Initial
value
Initial
value
REMOTE/LOCAL LOCAL Initial
value
LOCAL Initial
value
Initial
value
Initial
value
Block demiliter CRLF+
EOI
Initial
value
Initial
value
Initial
value
CRLF+
EOI
Initial
value
Initial
value
Initial
value
Initial
value
SRQ transmission OFF Initial
value
Initial
value
Initial
value
OFF Initial
value
Initial
value
Initial
value
SRER (*SRE) SMS25
5
Initial
value
Initial
value
0 Initial
value
Initial
value
Initial
value
DESER (DSE) 0 Initial
value
Initial
value
Initial
value
SESER (*ESE) 0 Initial
value
Initial
value
Initial
value
STB (*STB?) 0 Initial
value
Initial
value
Initial
value
0 Initial
value
Initial
value
Initial
value
Initial
value
SESR (*ESR?) 0 Initial
value
Initial
value
Initial
value
Initial
value
DESR (DSR?) Empty 0 Initial
value
Initial
value
Initial
value
Initial
value
Error log Empty Initial
value
Initial
value
Empty Initial
value
Initial
value
Initial
value
Initial
value
Number of error logs 0 Initial
value
Initial
value
0 Initial
value
Initial
value
Initial
value
Initial
value
Self-test result 0 0 Initial
value
Initial
value
Initial
value
Calibration mode OFF Initial
value
OFF Initial
value
Initial
value
Initial
value
Calibration data Initial
value
Saved
value
Table 3-13 Setting Parameter Initial Values (3 of 3)
6166 compatible 6166
USER parameter Source memory
Parameter
Initial
value
Power
ON
C
Z/
*RST
Initial
value
Factory
default
MENU
initializ
ation
Power
ON
*RST *CLS
C
(DCL)
*RCLx *SAVx RINI SINI RLOD RSAV RCLR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADCMT 6166 and is the answer not in the manual?

ADCMT 6166 Specifications

General IconGeneral
BrandADCMT
Model6166
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals