EasyManuals Logo

AMX NetLinx Studio User Manual

AMX NetLinx Studio
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
Setting Program Preferences
208
NetLinx Studio - Instruction Manual
Preferences dialog - Diagnostics tab
Use the options on the Diagnostics tab of the Preferences dialog to set default diagnostics preferences (FIG. 293).
FIG. 293 Preferences dialog - Diagnostics tab
Diagnostics options
Notification View and Diagnostics View
Display Line Numbers Toggles the display of line numbers in asynchronous notification displays (default = enabled).
Display Time Stamp Toggles the display of time stamps in asynchronous notification displays in one-second
increments (default = enabled). When enabled, the Display Milliseconds option causes
asynchronous notification time stamps to be displayed in milliseconds (default = disabled).
Display As These options convert unprintable characters (i.e. Control Codes) into either Hexadecimal or
Decimal values within the message (default = Hex Values).
• Hex values will display with a leading $ character. For example the message: STRING from
CHANNEL 6 - $0F$1D has two control codes converted to hexadecimal.
• Decimal values will display with a leading # character: STRING from CHANNEL 6 - #15#29.
Buffer File Options
Total Size Specify the total size of the two files that are used by the program to buffer the asynchronous
notification and system diagnostic messages. The number specified here will be divided evenly
between the two files.
• The range is 2 - 500 MB (default = 10).
• If you have less than 500 MB free on your disk, then the upper range value will be adjusted
according to the amount of free space on your disk.
• Your TEMP or TMP environment variables are used to determined the drive used for the two
buffer files.
Available Disc Space This read-only field indicates the current amount of free disc space available on your local hard
disc (c:). Use this number as reference if you are increasing the buffer file size.
Diagnostics and Notifications Output Displays Options
Read X lines from the
buffer every 1/4
second
Use this field to adjust the number of lines that will be read from the buffer every quarter-second
(default = 4)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX NetLinx Studio and is the answer not in the manual?

AMX NetLinx Studio Specifications

General IconGeneral
BrandAMX
ModelNetLinx Studio
CategorySoftware
LanguageEnglish

Related product manuals