R5910032 /00 Freya314
18.1 1 month maintenance actions
MAINTENANCE TYPE A (perform every month)
The 1 month maintenance actions, listed below, may be performed by a trained projectionist who is
familiar with potential hazards associated with the product.
No.
Maintenance action Remarks
1 Check the surface of the lens output side for dust. (it is not
needed to remove the lens from the projector). Only clean if
necessary.
Clean the lens output side in case dust
is clearly visible upon the surface.
Note: if the lens was removed from the
projector, a manual “Lens Home &
Return” action must be executed to
calibrate the position of the lens in
relation to the Lens Holder. This way
the references of the existing 'lens files'
remain valid. See user guide for more
information.
2 Check the porthole (both sides) for dust. Clean the porthole in case dust is
clearly visible upon the surface. Use an
optical cloth.
18.2 3 month maintenance actions
MAINTENANCE TYPE B (perform every three months)
The 3 month maintenance actions, listed below, may be performed by a trained projectionist who is
familiar with potential hazards associated with the product.
No. Maintenance action Remarks
1 Clean the back/side air inlet vents. Use a vacuum cleaner.
2 Clean the housing of your projector. Removal overall dust accumulation on
projector covers. See cleaning
instructions in this manual.
3 Verify the clock of the ICMP-X with a real time clock. Correct
the internal clock if it has drifted.
Note: This action is not required if NTP has been configured
on the ICMP-X. In this case NTP will automatically correct
the internal clock.
See user guide for detailed instructions
on NTP and clock correction.
Preventive maintenance actions