Connection cross section Connection
method
Torque Load
capacity
Motor PE BM5323
BM5325
BM5331
BM5332
BM5333
refer to motor cable Cable lug
fo
r M4
Min. 1.4 Nm
Max. 1.8 Nm
see
ZElectrical
data– as
from page
58
BM5326
BM5327
BM5328
BM5334
BM5335
refer to motor cable Cable lug
fo
r M5
Min. 2.2 Nm
Max. 3.0 Nm
BM537X refer to motor cable Cable lug
fo
r M8
Min. 10 Nm
Max. 13 Nm
Connection
cro
ss section
Connection
method
Load capacity
X200 (SEL
V/PELV)
24 V voltage supply
Max. 1.5 mm²
(2 wire 2 pin)
Plug connector,
spring-clamp con-
nection
Max. 2.0 A
plug connector, max. 16 A
Connection
cro
ss section
Connection
method
Load capacity
X1 (SEL
V/PELV)
Control inputs
BM503X-
XX0X
Max. 1.5 mm² Plug connector,
spring-clamp con-
nection
Max. 8.0 A
X2 (SEL
V/PELV)
DIO
Max. 1.0 mm² Plug connector,
spring-clamp
connection
Max. 8.0 A
X206 (SEL
V/PELV)
Supply for motor
t
emperature and
brake
all other
devices
Max. 1.5 mm² Plug connector,
sp
ring-clamp
connection
Max. 4 A
BM537X Max. 2,5 mm² Max. 16 A
Electrical connections
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
168
of 328