13DISPOSAL
13.1 Safety regulations
NOTE!
Baumüller products are not subject to the scope of application of the EU's Waste
Electrical and Electronic Equipment Directive (WEEE, 2012/19/EU). Hence,
Baumüller is not obligated to bear any costs for taking back and disposing of old de-
vices.
DANGER!
Risk of fatal injury from electrical current!
Stored electric charge.
Discharge time of the modular system = discharge time of the device with the longest
DC link discharge time in the modular system.
Refer to ZElectrical dataas from page 60.
Therefore:
m Do not touch before taking into account the discharge time of the capacitors and
electrically live parts.
m Heed corresponding notes on the equipment.
m If additional capacitors are connected to the intermediate circuit, the intermediate
circuit discharge can take a much longer time. In this case, the necessary waiting
period must itself be determined or a measurement made as to whether the equip-
ment is de-energized. This discharge time must be posted, together with an IEC
60417-5036 (2002-10) warning symbol, on a clearly visible location of the control
cabinet.