Monitoring functions
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
228
of 328
10.2
10.2 Monitoring functions
Monitoring function Warning/error
Warning
Error
Adjustable threshold
Adjustable reaction
Reaction
inhibit pulses
Power supply voltage
5)
Power supply undervoltage X
7)
X - - X
Power supply overvoltage X
7)
X - - X
Phase monitoring
5)
Phase failure X
7)
X - - X
Power supply failure X
7)
X X
7)
- X
1)
Power supply frequency too high
or too low
6)
X - - - -
Power supply synchronization lost
6)
- X - - X
No mains synchronization
possible
6)
- X - - X
Ground fault Fault current to ground
7)
- X - - X
Overcurrent Motor overcurrent
6)7)
- X - - X
Power supply/DC link overcurrent
5)7)
- X - - X
Power supply overcurrent
8)
- X - - X
Charging
9)
Time out charging - X - - X
Short-circuit in the DC link - X - - X
Discharging
9)
Time out quick discharge - X - - X
Power supply current during
discharging
- X - - X
DC link DC link overvoltage - X - - X
DC link relative undervoltage X
7)
X
8)
- - X
8)
DC link set value too low
5)6)
X - - - X
1)
Pulses are inhibited after a adjustable time period (not provided for BM51XX).
2)
Only if KTY/PT1000 sensors are used
3)
Threshold adjustable
4)
Reaction adjustable
5)
Not provided for BM53XX
6)
Not provided for BM50XX
7)
Not provided for BM51XX
8)
Only provided for BM51XX
9)
Not processed by BM51XX, only a message for the axis units.
X: Implemented