UL notes
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
88
of 328
4.3
4.3 UL notes
The notes below must be observed in case you consider UL 508 C.
ZRe
quired environmental conditions– on page 47
n Note the maximum s
urrounding air temperature.
n Use in a pollution
degree 2 environment only.
ZDe
sign– on page 81
n Axis units (BM5X23
, BM5X26, BM5X27, BM5X28, BM5X31, BM5X32, BM5X33, BM5X34,
BM5X35)are allowed to be used only in combination with mains rectifiers
(BM5031, BM5032, BM5043, BM5044, BM5174).
ZIn
stallation procedure– on page 141
n Internal overload protecti
on operates after exceeding 200 % of the motor full
load.
ZElectr
ical connections– as from page 157
n Position of
wiring terminals to indicate the proper connections for the power
supply, load, control circuit, and similar devices refer to ZPage
157–.
Connections of ZPa
ge 166– to ZPage 167–
n Note tightening to
rque values marked for field terminals.
ZRe
quirements for the connection cables– on page 128
n Use 60°/75°copper
wires only.
ZRe
quirements for the motor temperature sensors– on page 140
n Drives do not prov
ide motor overtemperature sensing.