Design and Operation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
87
of 328
4
Hardware configuration controller
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - EXX
01: BSCsafe Step 1 V.1 (for single and double axis),
with AIO, DIO, encoder, EtherCAT® (RJ45)
02: BSCsafe Step 1 V.2 (for single axis),
with AIO, DIO, encoder, EtherCAT® (RJ45)
04: BSCsafe Step 1 V.4 (for active mains converter),
without AIO, without encoder evaluation, without add-on module
05: Reserved
06: BSCsafe Step 1 V.1 (for single and double axis),
with AIO, DIO, encoder, EtherCAT® (RJ45), with additional +24 V supply for DIO and motor brake
07: BSCsafe Step 1 V.4 (for active mains converter),
without AIO, without encoder evaluation, without add-on module, with additional +24 V supply for DIO
08: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX), with AIO, DIO, encoder, fieldbus (RJ45)
09: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (RJ45), without DIO
10: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX)
with AIO, DIO, encoder, fieldbus (RJ45), both pulse enables are switched-on permanently
28: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (RJ45), 450 MHz
29: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (RJ45), without DIO, 450 MHz
30: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (RJ45), 450 MHz, both pulse enables are switched-on permanently
31: Reserved
58: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX), with AIO, DIO, encoder, fieldbus (M8)
59: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (M8), without DIO
60: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (M8), both pulse enables are switched-on permanently
61: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), DIO (but 4 normal digital inputs only, 2 of them for pulse enable),
without AIO, without 2nd encoder
62: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), without AIO, without DIO, without 2nd encoder
80: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (M8), 450 MHz, both pulse enables are switched-on permanently
81: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), DIO (DIO (but 4 normal digital inputs only, 2 of them for pulse enable), 450 MHz,
without AIO, without 2nd encoder
82: BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), 450 MHz, without AIO, without DIO, without 2nd encoder
Software option SoftDrivePLC
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - EXX,
and XX > 01
Safety Level
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - [EXX] - #XX
Mounting position of b maXX 5000
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - [EXX] - #XX - [M0],
M0: Mounting position turned by 180°

Table of Contents

Other manuals for Baumuller b maXX 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baumuller b maXX 5000 and is the answer not in the manual?

Baumuller b maXX 5000 Specifications

General IconGeneral
BrandBaumuller
Modelb maXX 5000
CategoryServo Drives
LanguageEnglish

Related product manuals