Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
171
of 328
7
7.15 Connections on the front side
7.15.1 Front side of mains rectifier unit BM50XX-XX0X-... without safety function
NOTE!
Description of BM5030 with safety function BM
5030-XX2X-...
see ZC.6.2 Con
nections front side BM5030 with safety function– as from page 313.
Figure 84: Connections front side BM50XX-XX0X-...
without safety function
X1 Digital inputs/outputs
1:M24V
2: Inhibit input
3: Quick discharge DC link voltage
4: Reset
5: Error
6: Ready-to-operate
X1 Digital inputs/outputs
Input current per input 7 mA
Input level High (12 … 28 V)
Output current per output 500 mA
Output level High (12 … 28 V)