Technical data
Instruction handbook bmaXX 5000
Document No.: 5.09021.19
75
of 346
3
Footnotes refer to Zpage 76.
BM5372-F BM5373-F BM5374-F BM5375-F BM5376-F
Input rated power
1)
64 kW 80 kW 95 kW
Input rated current (I
eff
)
1)
100A 125A 150A
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacitance (internal) 1230 µF 2050 µF
DC link discharge time
(internal DC link capacitance)
128 s 214 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
2kHz
4)
120A 150A 180A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
4kHz
4)
90 A 120 A 150 A 180 A
Output rated current (I
AC
RMS)
1) 2) 5)11)
at
8kHz
4)
63 A 84 A 105 A 130 A
Output rated current (I
AC
RMS)
1) 2) 5)11)
at
16 kHz
4)
45A 60A 75A 90A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
2kHz
4)
180 A 300 A 300 A 300 A 420 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
4kHz
4)
180 A 240 A 300 A 300 A 420 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
8kHz
4)
126 A 168 A 210 A 260 A 300 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
16 kHz
4)
90 A 120 A 150 A 180 A 200 A
Short-time operation KB 150 % 200 % 166 % 233 %
Max. length of time peak current
6) 10)
According dynamic temperature model
Power loss with regard to power supply Max.
650 W
Max.
900 W
Max.
1120 W
Max.
1300 W
Power loss with regard to control voltage
supply
7)
Max. 30 W
Requirements of the water cooling Refer to ZCoolingon page 58
Current of the integrated brake control
(option)
Max. 8.0 A
12) 13)