Electrical data
Instruction handbook bmaXX 5000
Document No.: 5.09021.19 Baumüller Nürnberg GmbH
66
of 346
3.4
m BM517X active mains rectifier unit
Footnotes refer to Zpage 68.
BM5173 BM5174
-XTXX-.. /-XIXX-.. / -XGXX-..
Input rated power
1)
39 kVA 69 kVA
Input rated current (I
eff
)
1) 2) 3)
56 A 100 A
Distortion factor of the input current (THD
I
)
1)
6%
Input peak current (I
eff
)
1) 2) 3)
84 A
for max. 120 s
11)
150 A
for max. 120 s
11)
PWM switching frequency
8kHz
DC link voltage
power supply dependent/rated
640 V
DC
to 760 V
DC
12)
DC link capacitance (internal) 2.5 mF
DC link discharge time
(internal DC link capacitance)
9)
Approx. 600 s
Total max. connectable capacitance
in the DC link (internal + external)
20 mF
Connection power at DC link
1) 5)
36 kW 64 kW
Peak power at DC link
4) 6)
54 kW
for max. 120 s
11)
96 kW
for max. 120 s
11)
Power factor (inductive only) 0.9 bis 1.0
Ready-to-operate after 50 s
Max. charge-up time 10 s
Quick discharge
10)
5s
External brake resistor R
B
Quick discharge resistor 55  R 72
Power loss with regard to power supply
7)
900 W 1600 W
Power loss with regard to
control voltage supply
8)
Max. 60 W
Cooling air requirement power heat sink 175 m
3
/h
Cooling air velocity power heat sink -
Cooling air requirement
internal space of device
35 m
3
/h

Table of Contents