EasyManua.ls Logo

Baumuller b maXX 5000 - Correction Values for the Output Current of the Mains Inverter BM50 XX, BM51 XX; Correction Value K H in Dependence on the Installation Altitude H, BM50 XX, BM51 XX

Baumuller b maXX 5000
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Instruction handbook bmaXX 5000
Document No.: 5.09021.19
49
of 346
3
3.3.4 Required environmental conditions
1)
If used in areas according to the category C2 of IEC 61800-3:2012, additional measures might be necessary. In this case the plant
manufacturer / user has to provide evidence these additional measures take effect and the in IEC 61800-3 required thresholds of the
category C2 are met.
2)
Refer to correction values at changed operation conditions at ZCorrection values at changed operating conditionson page 50.
Transport temperature range - 25 °C to + 70 °C
Transport climate class (K)
EN 60721-3-2
2 K 3
Storage temperature range - 25 °C to + 55 °C
Storage climate class
EN 60721-3-1
1 K 4
Operating environment
BM50XX
BM517X
BM519X
Industrial supply network C2
Industrial supply network C3
1)
,
refer to ZMounting of toroidal coresas from page 125
Industrial supply network C3
Operating temperature range Min. 5 °C to max. 55 °C
(with derating above 40 °C)
2)
Operating climate class
EN 60721-3-3
3 K 3
Installation altitude Up to 4000 m above MSL
(with derating above 1000 m)
2)
Humidity (operating)
EN 60721-3-3
Relative humidity: 5 % to 95 % non-condensed,
and
absolute humidity: 1 g/m
3
to 29 g/m
3
Ionizing and non-ionized radiation < measurable range
Vibration, shock and continuous shock
EN 61800-5-1, chapter 5.2.6.4 vibration test
Max. 1 g when operating
Degree of contamination
EN 61800-5-1, table 6, tab. 2
2
NOTICE!
Normally only a non-conductive dirt buildup occurs. Any conductive dirt buildup,
whether short-term or permanent, is prohibited and could lead to destruction of the
device. The customer is responsible for destruction resulting from dirt buildup of con-
ductive materials or matter.

Table of Contents