EasyManua.ls Logo

Baumuller b maXX 5000 - Page 322

Baumuller b maXX 5000
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function
Instruction handbook bmaXX 5000
Document No.: 5.09021.19 Baumüller Nürnberg GmbH
322
of 346
D.2
D.2 Function
The mains rectifier BM5030 with safety function converts the AC voltage of the power
supply (U
AC
) to the DC link voltage for the decentralized drive solutions BM2500 (U
DC
/
U
DC link
). The STO function is integrated in this device, disconnecting the DC link voltage
(U
DC
) of the mains rectifier to the axes units (U
DC link
). This is a two channel disconnec-
tion, i. e. a switch disconnects DC link + and another DC link - (see figure below).
The STO function is available via connector X2.
Figure 135: BM5030 with safety function
This STO function is available:
Type of automatic locking function (BM5030-XX2X)
In case of a fault of one switch, the device is locked automatically and remains in STO
state.
Electronics
Electronics
DC link
DC link +
DC link -

Table of Contents

Other manuals for Baumuller b maXX 5000

Related product manuals