Electrical data BM5030 with safety function
Instruction handbook bmaXX 5000
Document No.: 5.09021.19 Baumüller Nürnberg GmbH
324
of 346
D.3
D.3 Electrical data BM5030 with safety function
BM5030 with safety function
BM5030-XX2X-...
Input rated power
1)
6kVA
Input rated current (I
eff
)
1) 2) 3)
12 A
Distortion factor of the input current (THD
I
)
1)
110 % ± 10 %
Input peak current (I
eff
)
1) 2) 3)
12.5 A for max. 150 s
DC link voltage, power supply dependent/rated 540 V
DC
at U
power supply
= 3 x 400 V
Internal DC link capacitance C
int
330 µF, internal - connected upstream the STO
DC link discharge time (C
int
)
8)
Approx. 900 s
Maximum connectable DC link capacitance (external) C
ext
200 µF, external - connected downstream the STO
DC link discharge time (C
ext
)
10)
80 ms
Total maximum connectable capacitance in the DC link 3.15 mF,
internal + external
connected upstream the STO
9)
Waiting time between 2 charging processes
with external connected capacitance
Connection power at DC link
1) 5)
5kW
Peak power at DC link
4) 6)
7.5 kW for max. 150 s
Capacitance DC link to PE 150 nF
Ready-to-operate after 7s
Max. charge-up time 10 s
External brake resistor R
B
No connection
External brake resistor continuous power -
Quick discharge resistor -
Power loss with regard to power supply 50 W
Power loss with regard to control voltage supply
7)
Max. 25 W
Cooling air requirement power heat sink 40 m
3
/h
Cooling air velocity power heat sink -
Cooling air requirement internal space of device 8 m
3
/h
t
C
int
C
ext
+U
power supply
2
260 W
--------------------------------------------------------------------------------

Table of Contents