LED display BM5030 with safety function
Instruction handbook bmaXX 5000
Document No.: 5.09021.19 Baumüller Nürnberg GmbH
326
of 346
D.4
D.4 LED display BM5030 with safety function
BM5030-XX2X-...
Figure 136: Display/operating elements BM5030-XX2X-...
LED
H1
READY - Mains rectifier unit ready-to-operate:
green: Power supply and DC link voltage available, internally
OK
red: Power supply failure - automatically restart when power
supply returns.
blinking red: Power supply failure longer than 10 s - restart after
Power supply return has to be acknowledged (X1:4).
Refer to ZError acknowledgment of BM50XX– on page
254)
LED
H2
PHASE FAILURE
red: Phase failure
LED
H3
OVERTEMPERATURE
red: Overtemperature
LED
H4
DC-LINK ERROR
red: DC link error:
U
DC link
overvoltage or
U
DC link
overcurrent or
Inhibit input active
LED
H5
LED
H6
STO POWER
green:U
DC
is available
orange:U
DC
is not ready
red: Error
STO STATUS
green: Ready-to-operate
orange:U
DC link
charging procedure,
red:STO error