EasyManua.ls Logo

Baumuller b maXX 5000 - Page 333

Baumuller b maXX 5000
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BM5030 with Safety Function
Instruction handbook bmaXX 5000
Document No.: 5.09021.19
333
of 346
B
D.6.2 Connections front side BM5030 with safety function
X1 Digital inputs / outputs
BM5030-XX2X-...
Pin assignment
X1 Digital inputs/outputs
1:M24V
2: Inhibit input
3: Reserved
4: Reset
5: Error
6: Ready-to-operate
Figure 140: Connection X1 front side BM5030 with safety function
Pin
No.
Assignment
1 Dig. input/output GND 24 V
2 Digital input Inhibit input
1)
BM5030-XXX0
input is high active,
expects
NO contact
BM5030-XXX1
input is low active,
expects
NC contact
3 Digital input Reserved
4 Digital input Reset
5 Digital output Error
6 Digital output Ready-to-operate
Input current per input 7 mA
Input level High (12 … 28 V)
Output current per output 500 mA
Output level High (12 … 28 V)