EasyManuals Logo

Baumuller b maXX 5000 User Manual

Baumuller b maXX 5000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Electrical data
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
78
of 328
3.4
BM51XX
t
b
with I
P
= 100 % I
rated
t
p
with I
P
= 150 % I
rated
BM5174 S (air-cooled) 20 s 2 s
BM5174 C (cold plate) 0.5 s
BM53XX
t
b
with
I
b
= 60 % I
N
t
p
with
I
P
= 300 % I
N
t
p
with
I
P
= 200% I
N
t
p
with
I
P
= 150% I
N
t
b
with
I
b
= 60 % I
N
t
p
with
I
P
= 150 % I
N
BM5323 60 s(I
b
= 1.8 A) 4.8 s (I
P
= 9 A) 12.8 s (I
P
= 6 A) - 600 s (I
b
= 1.8 A) 240 s (I
P
= 4.5 A)
BM5325 60 s(I
b
= 3.6 A) 4.8 s (I
P
= 18 A) 12.8 s (I
P
= 12 A) - 600 s (I
b
= 3.6 A) 240 s (I
P
= 9 A)
BM5326 60 s(I
b
= 7.2 A) not allowed 10 s (I
P
= 24 A) - 600 s
1)
(I
b
= 7.2 A)
40 s
2)
(I
b
= 7.2 A)
150 s
1)
(I
P
= 18 A)
10 s
2)
(I
P
= 18 A)
BM5327 60 s(I
b
= 12 A) not allowed 10 s (I
P
= 40 A) - 600 s
1)
(I
b
= 12 A)
40 s
2)
(I
b
= 12 A)
150 s
1)
(I
P
= 30 A)
10 s
2)
(I
P
= 30 A)
BM5328 60 s(I
b
= 18 A) not allowed 10 s (I
P
= 60 A) - 600 s
1)
I
b
= 18 A)
40 s
2)
(I
b
= 18 A)
150 s
1)
(I
P
= 45 A)
10 s
2)
(I
P
= 45 A)
BM5331 60
s(I
b
= 7.2 A) not allowed 10 s (I
P
= 24 A) - 600 s
1)
(I
b
= 7.2 A)
40 s
2)
(I
b
= 7.2 A)
150 s
1)
(I
P
= 18 A)
10 s
2)
(I
P
= 18 A)
BM5332 60 s(I
b
= 12 A) not allowed 10 s (I
P
= 40 A) - 600 s
1)
(I
b
= 12 A)
40 s
2)
(I
b
= 12 A)
150 s
1)
(I
P
= 30 A)
10 s
2)
(I
P
= 30 A)
BM5333 60 s(I
b
= 18 A) not allowed 10 s (I
P
= 60 A) - 600 s
1)
I
b
= 18 A)
40 s
2)
(I
b
= 18 A)
150 s
1)
(I
P
= 45 A)
10 s
2)
(I
P
= 45 A)
BM5334 150 s
1)
(I
b
= 24 A)
50 s
2)
(I
b
= 24 A)
not allowed not allowed 30 s
1)
(I
P
= 60 A)
10 s
2)
(I
P
= 60 A)
150 s
1)
(I
b
= 24 A)
50 s
2)
(I
b
= 24 A)
30 s
1)
(I
P
= 60 A)
10 s
2)
(I
P
= 60 A)
BM5335 4.7 s (I
b
= 36 A) not allowed 1 s (I
P
= 120 A) - 150 s
1)
(I
b
= 36 A)
50 s
2)
(I
b
= 36 A)
30 s
1)
(I
P
= 120 A)
10 s
2)
(I
P
= 120 A)
BM5372-S 60 s(I
b
= 72 A) not allowed not allowed 30 s (I
P
= 180 A) - -
BM5372-F
BM5373-S 60 s(I
b
= 90 A) not allowed 12 s (I
P
= 300 A) 30 s (I
P
= 225 A) - -
BM5373 F
BM5374-S 60 s(I
b
= 108 A) not allowed not allowed 30 s (I
P
= 270 A) - -
BM5374 F
BM5375 F 60 s(I
b
= 108 A) not allowed not allowed 30 s (I
P
= 270 A) - -
BM5376-S 60 s(I
b
= 108 A) not allowed 12 s (I
P
= 300 A) 30 s (I
P
= 270 A) - -
BM5376-F
1)
Air-cooled
2)
Cooling by cold plate, refer to ZCoolingas from page 56.

Table of Contents

Other manuals for Baumuller b maXX 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baumuller b maXX 5000 and is the answer not in the manual?

Baumuller b maXX 5000 Specifications

General IconGeneral
BrandBaumuller
Modelb maXX 5000
CategoryServo Drives
LanguageEnglish

Related product manuals