3 608 878 300 Tightening Technology | Bosch Rexroth AG 403/641
System 350 | 3 608 878 300/2019-03
MID 0076 System error status
MID 0076 revision 001
Sent by: Tightening controller
The system error status is sent after a subscription for system errors from the tightening controller has been accepted.
Note: The system error status informs the superior computer that a system error is currently active in the connected
controller. Exactly one system error status message is sent for each active system error in the connected controller.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: Data 36 bytes
Possible response MID Error no. Comment
System error status acknowledgement 0077 –
Table 6–109: MID 0076 revision 001
Parameter Comments Bytes
System error status – 0: No system error active
– 1: A system error is currently active
The value consists of one ASCII character.
ID 01
2
Value range 0–1
Presetting -
Example:
System error
status
A system error is active
Value 0
1
Error number The value consists of four ASCII characters.
ID 02
2
Value range 0000 – 9999
Presetting -
Example:
Error number 105
Value 0105
4
Controller ready status Always NOK (=0), as no differentiation is made between controller and
tool.
The value consists of one ASCII character.
ID 03
2
Fixed value 0
1
Tool ready status Only NOK if error comes from the tool (error code from measurement
transducer 200 to 299 or ErgoSpin 350 to 399).
–1: OK
–0: NOK
The value consists of one ASCII character.
ID 04
2
Value range 0–1
Presetting -
Example:
Tool ready status OK
Value 1
1