3 608 878 300 Tightening Technology | Bosch Rexroth AG 415/641
System 350 | 3 608 878 300/2019-03
MID 0403 Deactivate automatic/manual mode
MID 0404
Selection automatic/manual mode
1)
MID 0410
AutoDisable setting request
2)
MID 0411
AutoDisable setting response
2))
Sent by: superordinate computer
The subscription to the change in operating mode (Logon automatic/manual mode, MID 0400) is reset.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 83 Activation for automatic/manual mode not available
1) This message is supported from version V2.200 of the Rexroth Tightening System 350.
Sent by:
superordinate computer
The operating mode is changed.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: Operating mode, 1 byte. The operating mode is identified by one ASCII character and can be as follows:
0: automatic mode
1: manual mode
Possible response MID Error no. Comment
Command accepted 0005 –
2) This message is supported from version V2.300 of the Rexroth Tightening System 350.
Sent by: superordinate computer
This command requests the setting of the automatic disabling function. It is set in the BS350:
– Compact system: OK/NOK counter configuration, option Block nutrunner
–KE: Tightening cell data/Open Protocol, option Disable application automatically
Note: -
Revision: 001 (Rexroth OP-Ford)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
AutoDisable setting response 0411 –
Sent by: Tightening controller
The setting is transmitted.
Note: -
Revision:
001 (Rexroth OP-Ford)
Data field: Data 4 bytes
Possible response MID Error no. Comment
Command accepted 0005 –