414/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.7.7.14 Operating mode messages
MID 0400 Activate automatic/manual mode
MID 0401 Upload automatic/manual mode
MID 0402 Upload automatic/manual mode acknowledgement
Sent by:
superordinate computer
As a consequence of this message, the superior computer is informed about every change in the operating mode of
the tightening system (between "automatic" and "manual") by means of a message (upload automatic/manual mode,
MID 0401). After confirmed logon (command accepted, MID 0005), the tightening controller moreover sends a
message (upload automatic/manual mode, MID 0401) with the current operating mode to the superior computer.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 82 Activation for automatic/manual mode already
available
Sent by: Tightening controller
After having changed the operating mode ("automatic" or "manual") the tightening controller uses this message to
inform the superior computer on the new operating mode.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: Operating mode, 1 byte. The operating mode is identified by one ASCII character and can be as follows:
0: automatic mode
1: manual mode
Possible response MID Error no. Comment
Upload automatic/manual mode
acknowledgement
0402 –
Sent by: superordinate computer
The superordinate computer acknowledges the change in operating mode (upload automatic/manual mode,
MID 0401).
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response: none