416/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0411 revision 001
6.7.7.15 PLC output signal messages
MID 0500 Subscription Output signal change
Table 6–113: MID 0411 revision 001
Parameter Comments Bytes
AutoDisable status Automatic disable status of
– Compact system: Option Block nutrunner with OK/NOK counter
– Modular system: Option Disable application automatically with
Tightening cell data/Open Protocol
Possible values:
– 00: not selected
– 01: selected
The value consists of two ASCII characters.
ID -
Value range 00–01
Presetting -
Example:
AutoDisable
status
Not set
Value 00
2
OK/NOK counter value Current counter value of OK/NOK counter as fixed value 00.
The value consists of two ASCII characters.
ID -
Value range 00
Presetting 00
Example:
OK/NOK
counter value
00
Fixed value 00
2
Data length revision 001
4
The messages in this section are supported as of version V2.200 of the Rexroth Tightening System 350.
Sent by: superordinate computer
As a consequence of this message, the superior computer is informed about every change in the configurable output
signals at the OP PLC module by means of a message (upload change in output signals, MID 0501). After confirmed
logon (command accepted, MID 0005), the tightening controller moreover sends a message (upload change in the
output signals, MID 0501) with the current assignment of the output signals to the superior computer.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 86 Activation for output signal change already available