CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–35 MN-CDM570A
Parameter
Type
(Instruction
Code and
Qualifier)
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Pattern
Valid only in CDM-570A Compatible Mode (CMO=1).
Sets or returns Tx BERT Pattern, in the form x, where:
0=1:1
1=2047
2=2^15-1
3=2^23-1
Example: <0/TBP=1 (Tx BERT Pattern is 2047)
TBP?
TBP#
(see Description of
Arguments)
Pattern
Valid only in CDM-570A Compatible Mode (CMO=1).
Sets or returns Rx BERT Pattern, in the form x, where:
0=1:1
1=2047
2=2^15-1
3=2^23-1
Example: <0/RBP=1 (Rx BERT Pattern is 2047)
RBP?
RBP#
(see Description of
Arguments)
0 or 1
Valid only in CDM-570A Compatible Mode (CMO=1).
Inserts 1 error in the form x, where:
x=1
BKE?
BKE#
(see Description of
Arguments)
Monitor
Valid only in CDM-570A Compatible Mode (CMO=1).
This command takes no arguments.
Restarts the BERT Monitor.
in bit errors
Valid only in CDM-570A Compatible Mode (CMO=1).
Returns BERT monitor results in bit errors, in the form x.xxE+yy
Example: <0/BRE?