SLM-5650B Satellite Modem
Revision 2
Front Panel Operation 5–25 MN-SLM-5650B
Option Settings
Set the target Eb/No for AUPC at 3.2 to 16.0 dB.
Set the maximum tracking rate at
0.5 to 6.0 dB per minute (in 0.5 dB
increments).
(CONFIG:) AUPC Local Carrier Loss Action
Carrier Loss: Local: HOLD
Remote: HOLD (E)
Use thearrow keys to select Local or Remote. Press [ENT].
Local Sets the action of the local modem when it loses carrier detect.
Sets the action of the local modem when the remote modem loses carrier
detect.
For either option, use the arrow keys to select HOLD, NOMINAL, or MAXIMUM.
Press [ENT] to finish.
(CONFIG:) AUPC Remote
Remote AUPC: Enable: Off BasebandL: Off
Tx Pattern: Off BER: Loss (E)
Use the arrow keys to select Enable, BasebandL, Tx Pattern, or BER. Press
[ENT].
Option Settings
Enable View or modify the status of the remote modem’s AUPC Enable.
View or modify the status of the remote modem’s I/O Loopback #1 setting.
View or modify the status of the remote modem’s Tx pattern substitution.
Note: In order to maintain compatibility with older Comtech EF Data modems, only
2047 pattern substitution is supported.
Monitor BER of the remote modem. The remote modem must have Tx Pattern set to
and the local modem must be transmitting a 2047 pattern.
Typical for all options, use the arrow keys to select operation as On or Off. Press
[ENT] to finish.