SLM-5650B Satellite Modem
Revision 2
Front Panel Operation 5–26 MN-SLM-5650B
(CONFIG:) AUPC ASYNC
ASYNC: TxBaud:1200 TxFormat:7E2 (E)
Type:232 RxBaud:1200 RxFormat:7E2
Use thearrow keys to select TxBaud, TxFormat, Type, RxBaud, or RxFormat.
Press [ENT]. Typical for each option, use the  arrow keys to scroll through the
available settings. Select your setting. Press [ENT] to finish.
Option
Settings
TxBaud
Select the Async Channel Tx Baud Rate:
110; 150; 300; 600; 1200; 2400; 4800; 9600; 19200; 38400.
TxFormat
Select the Async Channel Tx Character Format:
7N1; 7E1; 7O1; 7N2; 7E2; 7O2; 8N1; 8E1; 8O1; 8N2; 8E2; 8O2.
Type
Select the Async Channel communications protocol:
232; 485-2W; 485-4W.
RxBaud
Select the Async Channel Rx Baud Rate:
110; 150; 300; 600; 1200; 2400; 4800; 9600; 19200; 38400.
RxFormat
Select the Async Channel Rx Character Format:
7N1; 7E1; 7O1; 7N2; 7E2; 7O2; 8N1; 8E1; 8O1; 8N2; 8E2; 8O2.
Max Tx or Rx baud rate is limited to 1.875% of the primary data rate.
(CONFIG:) AUPC Logging
AUPC Statistics: View Clear-All
Config (E)
Use the arrow keys to select View, Clear-All, or Config. Press [ENT].
Option
Settings
View
Use the

arrow keys to view/scroll through the stored AUPC statistics. Press
[CLR] or [ENT] to return to the previous menu.
Clear-All
Use the arrow keys to select No or Yes to clear all stored AUPC statistics. Press
[ENT].
Config
Use the  arrow keys to set the interval that the statistics are stored. Valid settings
are 10 minutes through 90 minutes (in 10-minute increments), or Disabled. Press
[ENT].