SLM-5650B Satellite Modem
Revision 2
Appendix C C–32 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
CnC-APC FER
Reset
AFR= None Command only.
This command takes no arguments. Forces restart of the CnC-
APC FER measurement.
Example: AFR=
AFR=
AFR?
AFR*
AFR#
N/A N/A
CnC-APC
Activate/
Suspend
APC= 1 byte Command only.
Used to activate or suspend APC operation, in format APC-x,
where:
0 = No Action
1 = Activate APC
2 = Suspend APC
Example: APC = 1 (Activate APC)
APC=
APC?
APC*
APC#
N/A N/A
CnC-APC Max
Power Level
Increase
APL=
3 bytes
Command or Query.
CnC-APC maximum power level increase in form x.x, range from
0.0 to 9.9 dB, limited by Tx power level.
Example: APL = 3.9 (APC max power level increase is 3.9 dB)
APL=
APL?
APL*
APL#
APL?
APL=x.x
(see Description
of Arguments)
CnC-APC State
N/A
2 bytes
Query only.
Returns the state of APC operation. Return value is in form xx,
where:
00 = APC is not active
01 = No Solution
02 = OK ReBalance Done
03 = OK(Partial) CnC Ratio approaches limit
04 = OK(Partial) Local power approaches minimum value (IF)
05 = OK(Partial) Local power approaches minimum value (L-
Band)
06 = OK(Partial) Local power approaches maximum value
07 = OK(Partial) Local power approaches limit set by max
power level increase
08 = OK(Partial) Distant power approaches minimum value
N/A
APS?
APS=xx
(see Description
of Arguments)